dc.contributor.author | Knudsen, Hans Petter | |
dc.date.accessioned | 2009-01-08T12:10:03Z | |
dc.date.issued | 1985 | |
dc.identifier.uri | http://hdl.handle.net/11250/114504 | |
dc.description.abstract | High precision in hydroacoustic instruments for fisheries research demands high precision and
reliability in the test instruments. To simplify the test measurements, a special test unit has been
developed. The operating principles are described, and a technical description is given for this
special-purpose signal generator. Application of the unit is described in detail, and an easy way to
verify the accuracy of signal amplitude and frequency is recommended. Finally a computational
example to derive correction factors is given. | en |
dc.format.extent | 544195 bytes | |
dc.format.mimetype | application/pdf | |
dc.language.iso | eng | en |
dc.publisher | [Fiskeridirektoratets havforskningsinstitutt] | en |
dc.relation.ispartofseries | Fiskeridirektoratets skrifter, Serie Havundersøkelser | en |
dc.relation.ispartofseries | vol 17 no 16 | en |
dc.title | Time-Amplitude-Frequency (T-A-F) - A special electronic unit for measuring the TVG function of research echo sounders | en |
dc.type | Research report | en |
dc.source.pagenumber | s. 529-541 | en |