dc.contributor.author | Gytre, Trygve | |
dc.date.accessioned | 2012-08-17T11:04:58Z | |
dc.date.available | 2012-08-17T11:04:58Z | |
dc.date.issued | 1989 | |
dc.identifier.citation | This report is not to be cited without prior reference to the author | no_NO |
dc.identifier.uri | http://hdl.handle.net/11250/104585 | |
dc.description.abstract | During a survey in Lofoten in may 1989 a new miniature CTD
which is being developed at the Inst. of Marine Research was
mounted to the ship`s ordinary serial 1223 CTD- profiler on 10
different CTD- stations. Using the NB CTD as a reference and
compensating for differences in sampling rate, the data
presented from the two instruments when being in the same
water volumes were compared. The experiments showed
occational differences in the measurements of maximum 0.18
degr. C in temperature and 0.18 mmho/cm in conductivity.
lf the miniature CTD is calibrated against the NB CTD and the
water is homogenous, the differences in reading between the two
instruments may be reduced to within +/- 0.02 degrees C and+/-
0.025 mmho/cm. | no_NO |
dc.language.iso | eng | no_NO |
dc.publisher | ICES | no_NO |
dc.relation.ispartofseries | ICES CM Documents;1989/C:24 | |
dc.subject | gear experiments | no_NO |
dc.subject | redskapsforsøk | no_NO |
dc.title | A field intercomparison between a miniature CTD and the Neil Brown serial 1223 CTD- profiler | no_NO |
dc.type | Working paper | no_NO |
dc.subject.nsi | VDP::Agriculture and fishery disciplines: 900::Fisheries science: 920::Fisheries technology: 924 | no_NO |
dc.subject.nsi | VDP::Mathematics and natural science: 400::Geosciences: 450::Oceanography: 452 | no_NO |
dc.source.pagenumber | 8 s. | no_NO |